Gain: Difference between revisions
Line 30: | Line 30: | ||
== Variable Gain / Manual Gain / External Gain Adjustment Circuit (EGAC) == | == Variable Gain / Manual Gain / External Gain Adjustment Circuit (EGAC) == | ||
The external gain adjustment circuit (EGAC), | The external gain adjustment circuit (EGAC), commonly known as ''manual gain'', is a feature that enables users to adjust the gain of an image intensifier using a potentiometer built into the housing.. [[MX-11769]] is the most popular tube format to feature manual gain, as well as a subtype of the [[MX-10160]] format used in the [[AN/PVS-31]]. | ||
It is important to note that even though tubes equipped with manual gain offer users some control, they also always come equipped with autogain, as these two features are not mutually exclusive. | |||
== System Gain == | == System Gain == |
Revision as of 14:34, 28 March 2023
Gain, also called brightness gain or luminance gain, is the measurement of the increase in brightness between the input and the output of an image intensifier tube.
Specification
There are two different units used to specify gain, imperial and metric.
Imperial
The imperial units used to specify gain are foot-lambert per foot-candle ().
They are used by all manufacturers and retailers as well as government organizations in the United States. However, the popularity extends beyond the United States due to the significant influence of the country in the night vision industry worldwide.
Measurement
To measure gain in accordance to the MX-10160/AVS-6 specification, the photocathode is exposed to of input light. A photometer is then used to measure the luminance (brightness) of the phosphor screen (in ). The resulting value is divided by to obtain the gain in .[1]
To further test auto brightness control, the same procedure is usually repeated with .
Metric
The metric units used to specify gain are candela per square-meter per lux ().
Most notable for using metric units in all specifications is the European image intensifier manufacturer Photonis Technologies SAS.
Conversion
To convert between metric and imperial units the following formula can be used.
So, a gain of 10,000 is equivalent to roughly 31,416 .
Autogain / Automatic Brightness Control (ABC)
All modern image intensifier tubes are equipped with automatic brightness control (ABC), also known as autogain. This feature automatically down-adjusts the gain of the image intensifier in brighter environments to ensure a consistent viewing experience for the user. It is unclear, however, whether ABC also helps to protect the image intensifier from damage, such as burn-in, in very bright environments.
Variable Gain / Manual Gain / External Gain Adjustment Circuit (EGAC)
The external gain adjustment circuit (EGAC), commonly known as manual gain, is a feature that enables users to adjust the gain of an image intensifier using a potentiometer built into the housing.. MX-11769 is the most popular tube format to feature manual gain, as well as a subtype of the MX-10160 format used in the AN/PVS-31.
It is important to note that even though tubes equipped with manual gain offer users some control, they also always come equipped with autogain, as these two features are not mutually exclusive.
System Gain
System gain refers to the gain of the entire night vision device instead of only the image intensifier tube, including all lens systems.
As such, system gain does not measure the luminance of the phosphor screen, but the brightness of the light projected by the ocular. As such, in the imperial system, it is specified using foot-lambert per foot-lambert (), and in the metric system using lux per lux ().
Both in imperial and metric, the system gain can be estimated using the following formula.[2]